Por favor, use este identificador para citar o enlazar este ítem: http://dspace.pucesi.edu.ec/xmlui/handle/11010/312
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorArciniega Chicaiza, Álvaro Mauricio-
dc.date.accessioned2019-05-10T18:19:05Z-
dc.date.available2019-05-10T18:19:05Z-
dc.date.issued2019-03-
dc.identifier.other074629-
dc.identifier.urihttps://dspace.pucesi.edu.ec/handle/11010/312-
dc.descriptionEl plomo dentro del organismo en altas cantidades puede ser perjudicial para el cuerpo, el límite máximo permisible en humanos es de 10 μg.dl-1 si se excede este nivel puede conllevar a sufrir dolores de cabeza, náusea, mareo y hasta la muerte; esta investigación ayuda a mitigar la presencia excesiva de metales pesados y la contaminación que conlleva su mal manejo, con ayuda de bacterias de ambientes fríos psicrófilas se verificó si es viable o no un proceso de biorremediación. Para verificar la viabilidad de biotransformación de las bacterias psicrófilas se realizó un proceso de aislamiento de cepas bacterianas mediante agar nutritivo LB, el objetivo fue reproducir las bacterias, se obtuvo una colonia por cada siembra en cada caja Petri al cabo de 72 horas, a temperatura ambiente en la cámara de flujo laminar “laboratorio” (19°C), refrigeración (3°C); no se obtuvo resultado positivo a temperatura de estufa (29°C), este último resultado se debe a que este grupo de bacterias son de ambientes fríos y su desarrollo óptimo es de 0 a 15°C. Las muestras fueron sometidas a una concentración de plomo de 0.1 mg.l-1 que es el porcentaje de plomo máximo permisible en el cuerpo humano, posteriormente se fue duplicando sus concentraciones es decir 0.2, 0.4 y 0.8 mg.l-1 todas las muestras fueron sometidas a las condiciones de temperaturas antes mencionadas con el fin de verificar la capacidad de biotransformación y resistencia de las bacterias psicrófilas, este estudio comprobó que la temperatura es un factor determinante. Se comprobó el porcentaje de reducción de plomo en las muestras positivas obtenidas, este análisis se lo realizó en los laboratorios de la PUCESI mediante la técnica de llama en el equipo de absorción atómica obteniendo un resultado positivo en las muestras: “Cascada Mirlos” CM (1.80), “Punto Agua” PA (1.87) y “Punto Hielo” PH (2.40) estos valores corresponden al residuo del 100% en cada valor, obtenidos estos resultados se llegó a la conclusión que las bacterias del punto CM a una concentración de 0.08 mg.l-1 fueron las más efectivas en este proceso.es_ES
dc.description.abstractLead within the body in high amounts can be harmful to the body, the maximum permissible limit in humans is 10 μg.dl-1 if this level is exceeded it can lead to headaches, nausea, dizziness and even death; Due to this problem, which is becoming more and more evident, this research was carried out to help mitigate the excessive presence of heavy metals and the contamination that this mismanagement entails, with the help of bacteria from cold psychrophilic environments, it was verified whether a process is viable or not. of bioremediation. To verify the viability of biotransformation of the psychrophilic bacteria, a process of isolation of bacterial strains was carried out by means of LB nutritive agar in which the objective was to reproduce the bacteria, a colony was obtained for each sowing in each Petri dish after 24 hours, at room temperature (19°C), refrigeration (3°C); no positive result was obtained at stove temperature (29°C), this last result is due to the fact that this type of bacteria are from cold environments, that is, their optimum development is from 0 to 15 ° C. The samples were subjected to a concentration of 0.1 mg.l-1 which is the maximum permissible percentage of lead in the human body, later it was doubling its concentrations ie 0.2-0.4 and 0.8 mg.l-1 All the samples were subjected to the temperature conditions mentioned above in order to verify the capacity of biotransformation and resistance of the psychrophilic bacteria, this study proved that the temperature is a determining factor for its development since it was positive for the ambient and refrigeration temperatures and negative with a 100% mortality rate for the stove temperature. The percentage of lead reduction in the positive samples obtained was checked, this analysis was performed using the atomic absorption technique obtaining a positive result: CM (1.80), PA (1.87) and PH (2.40) these values correspond to the residual of 100% in each value, obtained these results it was concluded that the bacteria of the CM point were the most optimal in this process.es_ES
dc.description.sponsorshipECAAes_ES
dc.language.isoeses_ES
dc.publisherPontificia Universidad Católica del Ecuador Sede Ibarraes_ES
dc.relation.ispartofseriesT/589.9/A674ac/2019;074939-
dc.subjectPsicrófilases_ES
dc.subjectCascada Mirloses_ES
dc.subjectPunto aguaes_ES
dc.subjectPunto hieloes_ES
dc.titleAislamiento de cepas bacterianas de ambientes fríos para remoción de plomo en condiciones de laboratorioes_ES
dc.typeThesises_ES
Aparece en las colecciones: CIENCIAS AMBIENTALES Y ECODESARROLLO

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
TESIS ÁLVARO ARCINIEGA.pdfTESIS/AARCINIEGA1,58 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.